Ask a Librarian

Threre are lots of ways to contact a librarian. Choose what works best for you.

HOURS TODAY

10:00 am - 4:00 pm

Reference Desk

CONTACT US BY PHONE

(802) 656-2022

Voice

(802) 503-1703

Text

MAKE AN APPOINTMENT OR EMAIL A QUESTION

Schedule an Appointment

Meet with a librarian or subject specialist for in-depth help.

Email a Librarian

Submit a question for reply by e-mail.

WANT TO TALK TO SOMEONE RIGHT AWAY?

Library Hours for Thursday, November 21st

All of the hours for today can be found below. We look forward to seeing you in the library.
HOURS TODAY
8:00 am - 12:00 am
MAIN LIBRARY

SEE ALL LIBRARY HOURS
WITHIN HOWE LIBRARY

MapsM-Th by appointment, email govdocs@uvm.edu

Media Services8:00 am - 7:00 pm

Reference Desk10:00 am - 4:00 pm

OTHER DEPARTMENTS

Special Collections10:00 am - 6:00 pm

Dana Health Sciences Library7:30 am - 11:00 pm

 

CATQuest

Search the UVM Libraries' collections

UVM Theses and Dissertations

Browse by Department
Format:
Online
Author:
Popiel, Caroline Rose
Dept./Program:
Electrical and Biomedical Engineering
Year:
2020
Degree:
M.S.
Abstract:
Renewable energy is an important and growing percentage of the total power supply. Additionally, non-wires alternatives, which are meant to substitute for the construction of more transmission lines, are increasing in quantity as the demand for electrical power increases. Many non-wires alternatives take the form of renewable energy resources and batteries, and are distributed over short distances through neighborhoods and communities. Inverters are used to connect these DC resources to the AC grid. However, there is growing industry concern that the disconnect function that is inherent to interconnection standards for inverter-based resources has the potential to result in a cascading failure if voltages deviate significantly from nominal. This thesis studies the conditions under which a cascading inverter collapse of this sort could occur. More specifically, it identifies engineering design parameters, such as time constants, that influence the speed and nature of these cascades, using a new model called Time-Dependant Inverters Model (TiDIM). While this model is preliminary, the results suggest that risk increases with a number of factors including large transmission or distribution line impedances, a large variance in inverter voltage setpoints, and an inappropriate number of inverter-based resources that can contribute to supplying too much or not enough power. Next, the thesis characterizes the risk at which one may expect this sort of event to occur as a function of line impedance and the resultant voltage magnitude. It is found that a greater proportion of inverter-connected power in the grid is associated with a higher probability of collapse, and a greater variance in inverter behavior is associated with a wider transition band, which is defined in this thesis as the range of impedances/voltages where the probability of collapse is an uncertain. Lastly, the thesis identifies cost-effective strategies to reduce the likelihood of such an event.