Ask a Librarian

Threre are lots of ways to contact a librarian. Choose what works best for you.

HOURS TODAY

Closed

Reference Desk

CONTACT US BY PHONE

(802) 656-2022

Voice

(802) 503-1703

Text

MAKE AN APPOINTMENT OR EMAIL A QUESTION

Schedule an Appointment

Meet with a librarian or subject specialist for in-depth help.

Email a Librarian

Submit a question for reply by e-mail.

WANT TO TALK TO SOMEONE RIGHT AWAY?

Library Hours for Saturday, November 23rd

All of the hours for today can be found below. We look forward to seeing you in the library.
HOURS TODAY
Closed
MAIN LIBRARY

SEE ALL LIBRARY HOURS
WITHIN HOWE LIBRARY

MapsM-Th by appointment, email govdocs@uvm.edu

Media ServicesClosed

Reference DeskClosed

OTHER DEPARTMENTS

Special CollectionsClosed

Dana Health Sciences Library10:00 am - 6:00 pm

 

CATQuest

Search the UVM Libraries' collections

UVM Theses and Dissertations

Browse by Department
Format:
Online
Author:
Allen, Dana
Dept./Program:
Plant and Soil Science
Year:
2017
Degree:
MS
Abstract:
Lake Champlain is a major economic driver for Vermont's tourism economy, as well as a primary source of drinking water for many of the state's residents but nutrient pollution represents a potential threat to ecosystem health and economic well-being. From December 2011 to December 2012 a field trial of an EAF steel slag filter was assessed for its feasibility in treating wastewater originating from Swan Valley Cheese (SVC), in Swanton, VT. The study focuses on a period of the filter's operation from May 4 to October 10, 2012. The plant generates approximately 20,000 gallons per day of high P concentration wash water which is treated in an open aerated lagoon. The filter treated effluent from this lagoon. The major goals of this research were to conduct a field trial of an EAF steel slag filter to evaluate its effect on total P (TP), dissolved reactive P (DRP), and total suspended solids (TSS). Research was also conducted on pH reduction for filter effluent. Results indicate that the filter removed 95.83% of TP, 96.65% of DRP, and 52.25% of TSS. Average pH effluent was measured at 10.12 ±1.55. Additionally, a field study was conducted on sampling two unlined bioretention systems treating urban stormwater runoff. Methods used are presented and methodological considerations for future studies are presented to guide researchers in more effective and efficient methods for obtaining influent and effluent samples from bioretention systems that are not necessarily designed for sampling.